Desconto de 5000 handheld lcr meter user manual

Lutron electronics lcr9184 operation manual pdf download. When measuring incircuit components, first deenergize the circuits before connecting to the test leads. U1733c seems to have wider measurement range, but 20000 counts to bks 40000. Dualdisplay handheld lcr meters models 878b and 879b specifications cont. For more information about handheld capacitance and lcr meters, please visit keysight u1700 series handheld capacitance and lcr meters. The de5000 lcr meter is very nice, accurate and flexible, easy to use and low cost. However, it can be set to auto or manual ranging by pressing the range hold key. Shop our best value digital lcr meter on aliexpress. U1733c 100hz120hz1khz10khz100khz handheld lcr meter. When i received it, it would not turn on with the power button. Lcrii can control a meter system as a standalone unit, or it can be used as a slave to a host contoller such as a process controller or an incab data management system. Exo handheld general operation startup push the key to turn on the handheld.

For additional important information about serial numbers, read. Extechs passive component lcr meter 380193 is a favorite in manufacturing facilities for quality control and product testing, as well as for individual users that need to validate and sort a range of components in custom projects. U1731cu1732cu1733c users guide v warning use this meter only as specified in this manual. View and download deree de5000 instruction manual online. Use the meter only as specified in this operating manual, otherwise the protection provided by the meter may be impaired. The de5000 is a portable, highperformance lcr meter that is fullfeatured yet cost effective. No english user manual remember to calibrate before use steps are described in user manual verified purchase. Keysights handheld capacitance meters and portable lcr meters enable you to perform quick, basic lcr measurements at your convenience. If the handheld does not turn on, make sure that the battery pack is correctly installed and charged. I compared capacitance measurements i got from the de5000 with readings from a calibrated fluke 87v and they were comparable. Otherwise, the protection provided by the meter may be impaired. It measures in true 4wire kelvin mode and rivals the capabilities and options of many of its bench counterparts. Electronic page numbers original page numbers 23, 24, etc. In this manual, a warning identifies conditions and actions that pose hazards to the user, or may damage the meter or the equipment under test.

Deree de5000 handheld bridge lcr meter de5000 ebay. Lcrii overview this manual provides instructions for the initial setup, the calibration, and the operation of lectrocount lcrii sof tware, also known as sr260 firmware. Overview this multifunction lcr meter is a portable. With battery external power supply, the meter is ideal for field and portable applications, such as component inspection at fixed place, and immediate measurement by buyer and maintenance.

Confirm that the circuits have been powered off and all capacitors in the circuits been discharged before measuring incircuit components. Discharge all charging elements, such as capacitors, before testing. This wasnt a definitive test of the de5000s capability. It also offers multiple test frequencies that are selectable. With a black and yellow combination, the meter can measure high accuracy.

Do not apply more than the rated voltage, as marked on meter, between terminals or between any terminal and earth ground. This meter is for indoor use, altitude up to 2,000 m. Rs, rp, cs, cp, ls, lp, phase angle, dissipation factor, quality factor auto select series or parallel test mode auto select 100hz1khz10khz test frequency, 0. Shop digital lcr meter great deals on digital lcr meter on. The meter is safetycertified in compliance with en61010 iec 10101 installation category ii cat. Navigation the exo handheld contains menus to change userdefined options, functions, and parameters. Gain better noise immunity and save money with smd tweezer option. Lcr ii overview this manual provides instructions for the initial setup, the calibration, and the operation of lectrocount lcr ii sof tware, also known as sr260 firmware. The liquid controls lectrocount lcrii is a microprocessorbased electronic meter register available in a division 1 or a division 2 enclosure. Digital handheld lcr meter quality rlc meter 100khz 10khz. You are covered by the ebay money back guarantee if you receive an item that is not as described in the listing.

Always use proper terminals, switch position, and range for measurements. The chroma 1102111021l are the most costeffective digital lcr meters, providing 100hz, 120hz, 1khz, and 10khz test frequencies for the 11021 and 1khz, 10khz, 40khz, 50khz test frequencies for the 11021l. Stylish, handheld and updated is main feature of the model. The warnings and precautions should be read and well understood before the instrument is used. Please read this instruction manual before using the meter and keep it. Navigation the exo handheld contains menus to change user defined options, functions, and parameters. I discovered that if i removed the battery and put it back in it powered up immediately, and seemed to work properly. The liquid controls lectrocount lcr ii is a microprocessorbased electronic meter register available in a division 1 or a division 2 enclosure. What makes this device special is its lab grade accuracy, rugged construction, overall reliablity, ease of use, well written instructions and plenty of on line help.

This allows the user to measure the lcr components in auto lcr mode without having to select the type of measurement. And dont miss out on limited deals on digital lcr meter. Range max display cx accuracy df dx user manual may cause damages to this instrument, affect the measurement accuracy or even physically harm the user or anyone else. The de6000 handheld lcr meter has automatic impedance selection. It is also suitable for applications where there is a need to alignadjust capacitanceinductanceresistance. Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are fully familiarized with how best to operate the meter as accurately and safely as possible. Do not block or obstruct the cooling fan vent opening. The probe assembly provided with the product are for use with meter power requirements.

Lcr ii can control a meter system as a standalone unit, or it can be used as a slave to a host contoller such as a process controller or an incab data management system. Instruction manual x1 carry case x 1 additional accessories for with usb function. Better yet, the battery lasts up to 16 hours, ideal for testing on the go. Thank you for purchasing the multifunction lcr meter. Lcr800 user manual 6 safety guidelines general guideline caution do not place any heavy object on the lcr800. De5000 portable, fullfeatured lcr meter user and service manual. The de5000 uses kelvin connections and the ability to calibrate out test lead offsets. Dual handheld lcr meter th2822th2822ath2822c instruction manual. Range max display cx accuracy df dx mete r dual display autoranging dual displays provide quick tested results readouts, with l. With the u1730 series, you can perform quick, basic lcr measurements at your convenience, without burning a hole in your pocket. Use the meter only as specified in this manual or the protec tion by the meter might be impaired. De5000 portable, fullfeatured lcr meter user and service.

This lcr meter features automatic lcr selection, a sorting mode, and selectable test frequencies. Open open, short short and quit quit are selected and displayed automatically by the meter according to the impedance value of the device under test. U1700 series handheld capacitance and lcr meters keysight. Bk 878b 40,000 count dual display handheld lcr meter. Manual multifunction lcr model km 520b operation manual.

Buy de5000 handheld lcr meter discontinued replaced by de6000. It also features a sorting mode, allowing users to quickly sort components. The power for the meter is supplied with a single standard 9v battery. U1731cu1732cu1733c user s guide v warning use this meter only as specified in this manual. This symbol is a warning and indicates that the user should refer to the operating instructions located in the manual. Th2821b operation manual 18 will be displayed in the secondary parameter display area. Digital lcr meter handheld bridge lcr multimeter tool. Shop digital lcr meter great deals on digital lcr meter. Agilent 4285a precision lcr meter including option 001, 002, 201, 202, 301 maintenance manual serial numbers this manual applies directly to instruments whose serial number prefix is 3009j, and whose rombased firmware is version 01. When lcr measurement mode is selected, one of the test frequencies, 100 hz, 120 hz, 1 khz, 10 khz, 100 khz or 200 khz, may be selected on all applicable ranges. How does the bk precision 879b compare to agilents u1733c. It appears at first glance of the comparison photos that its all just a marketing act done by iet to distance itself from the de5000 due to. Avoid severe impact or rough handling that leads to damaging the lcr800.

This lcr meter can transfer data to a pc via a standard, fully isolated, optical irusb interface. This lcr meter is a 19999 9999 counts dual display, high see manual. Agilent 4285a precision lcr meter maintenance manual. Extech 380193 passive component lcr meter tequipment. To accommodate various test requirements, the de6000 handheld lcr meter offers selectable test frequencies. Small problem and fix of eevblog user with its recent deree 5000. View and download lutron electronics lcr 9184 operation manual online.

1504 1535 1273 290 1216 15 1356 1211 822 1006 1319 802 1427 932 909 159 273 104 1461 414 1455 449 540 942 982 1184 1064 1240 349 1069 538